Before an adapter card or module can be shut down, all port associations with this adapter card or module, for example SAPs and IP interfaces, must be shut down first.ġ2-port Serial Data Interface card, version 1ġ2-port Serial Data Interface card, version 2ġ2-port Serial Data Interface card, version 3Ĩ-port Gigabit Ethernet Adapter card, version 1Ĩ-port Gigabit Ethernet Adapter card, version 2Ĩ-port Gigabit Ethernet Adapter card, version 3Ĥ-port OC3/STM1 Clear Channel Adapter cardĤ-port OC3/STM1 / 1-port OC12/STM4 Adapter cardġ0-port 1GigE/1-port 10GigE X-Adapter card, version 1ġ0-port 1GigE/1-port 10GigE X-Adapter card, version 2Ĥ-port T1/E1 and RS-232 Combination module The adapter card or module must be administratively shut down before it can be deleted from the configuration. The no form of this command deletes the adapter card or module from the configuration. The alarm is cleared when the error condition ceases. A low severity trap is issued if an administratively disabled adapter card or module is removed.Īn alarm is raised if partial or complete adapter card or module failure is detected. This alarm is cleared if either the correct adapter card or module type is inserted or the configuration is modified. A high severity alarm is raised if an administratively enabled adapter card or module is removed from the chassis. This alarm is cleared when the correct adapter card or module is inserted or the configuration is modified. To modify an MDA or module slot, shut down all port associations.Ī medium severity alarm is generated if an adapter card or module is inserted that does not match the adapter card or module type configured for the slot. Only one adapter card or module can be provisioned per MDA or module slot. A maximum of two modules can be installed in a 7705 SAR-H chassis. One module can be installed in a 7705 SAR-M chassis. Ports can be configured once the adapter card or module is properly provisioned.Ī maximum of 6 adapter cards can be installed in a 7705 SAR-8 Shelf V2 chassis, and a maximum of 12 adapter cards and 4 XMDA adapter cards can be installed in a 7705 SAR-18 chassis. The adapter card or module can be preprovisioned, but it must be provisioned before ports can be configured. This mandatory command provisions a specific adapter card or module type to the device configuration for the slot. All dependencies to ports on this card must be shut down and removed from the configuration before issuing the no card-type command. This operation requires that the card be administratively shut down. The no form of this command removes the card from the configuration. An error message is generated if an attempt is made to provision a card type that is not allowed. Port and adapter card information must be shut down.Ī card can only be provisioned in a slot if the card type is allowed in the slot. To reconfigure a slot position, use the no form of this command to remove the current information. On the 7705 SAR, the card type is always iom-sar.Ī card must be provisioned (configured) before an adapter card or port can be configured.Ī card can only be provisioned in a slot that is vacant, which means that no other card can be provisioned for that particular slot. The card type can be preprovisioned, meaning that the card does not need to be installed in the chassis. This mandatory command is the second step in activating the IOM software: designating the card type.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |